Re: Intel S2600GZ Server SSD Issue

$
0
0

Based on the information provided, the Intel® RAID Controller card RS2WC040 only has 1x SAS channel that would support the first 4 drives on the side of the backplane where you plug in the cable that goes from the RAID controller to the backplane.

 

If you inspect the connectors of the backplane (see example), you will see that there is more than one SAS connector. Each one of them would support up to 4 drives.

 

S2600GZ MiniSAS connectors.PNG

In this case, I would suggest moving the drive to the other side, where the other 2 drives are installed or you may also consider installing the SSD internally as the example listed below.

 

S2600GZ SSD mount.PNG

 

 

If you prefer to run your Operating System through the hardware RAID solution, you may also considering using the Intel® RAID Controller RS2WC080 instead.