Hello Sergey,
Thank you for contacting Intel Customer Support.
Bases in all the information you shared, I noticed you flashed the last versions for the S2600CP. At his point, you are in the right path, BMC is generating invalid readings.
I would like to recommend to flash again but now using Intel Server Board S2600CP Firmware Package for EFI.
Here the update instructions:
- Unzip the contents of the update package and copy all files to a folder on a USB flash drive
- Insert the USB flash drive to any available USB port on the server system to be updated
- Boot the Server to the EFI shell. This can be accessed via the <F2> BIOS setup utility during POST.
- Run the command "map -r" in the EFI shell to mount the USB flash drive
- Run the command "fs0:" to change folders to the USB flash drive. The USB flash drive
may also mount to fs1: depending on other installed devices. The number of "fs#" is
dependent on the result of command "map -r"
- Change folders to the folder storing the update package files
- Run the command "Startup.nsh" to start updating all the firmware and BIOS updates
Waiting to hear your results.
faugub_intel
#iwork4intel
↧
Re: s2600cp BMC Firmware Failure reported, fans at 100%
↧