Re: Intel Server Motherboards interfacing with Redundant Power Supplies from...
Yes the board does support monitoring PSU status, but you'll need to connect the 5-pin PS AUX cable from PSU to the board (J9A1), which provides I2C monitoring of the power supply. Does your PSU come...
View ArticleRe: S2600CO & pass-through disks
Hello, Windows XP x64 successfully installed with a disk connected on SATA (White) port.When trying to install XP x64 on a disk connected to one of SAS/SATA blue port (0-3), we have a problem with the...
View ArticleRe: S2600CO & pass-through disks
Most likely your issue is related to this:Server Products — Failure to load driver during installation from some USB floppy drives Possible workaround:Server Products — Utilizing a...
View ArticleRe: Intel Server Motherboards interfacing with Redundant Power Supplies from...
The power supply does have a 5 pin PS AUX cable. Is Intel calling the PS AUX what others are referring to as the PMBus? If so, I should be able to make the connection between the PMBus...
View ArticleNETIO.SYS error, who to fix?
Olá,Estou com este erro no meu servidor poweredge 1850 com o sistema operacional windows server 2008 R2 instalado e atualizado.Sempre que vou tentar abrir o vmware server 2.0.2 e iniciar uma máquina...
View ArticleRe: Intel Server Motherboards interfacing with Redundant Power Supplies from...
Did you run FRUSDR update AFTER plugging that AUX power cable?
View Articlesyscfg help with linux
Hi,I'm using syscfg Version 11.0 Build 12 on CentOS 6.5 on a S2600GZ motherboard. I'm having problems getting useful output from syscfg For example,# /usr/bin/syscfg/syscfg /d biossettings An unknown...
View ArticleRe: syscfg help with linux
You can try a later version: https://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=23126&lang=eng
View ArticleRe: Intel Server Motherboards interfacing with Redundant Power Supplies from...
a couple common reasons 3rd party PSU have issues are:I2C address of the PSU and PDB is incorrect.BMC expects :PSU1 at B0 device \ A0 FRUPSU2 B2 device \ A2 FRUPEC (Packet Error Checking) not enabled...
View ArticleIs my plan to increase raid drive sizes and change partition sizes workable?
I am going to replace the raid drives on my server and wanted to know if my plan will work before I actually attempt it. I have a server board S1200BTL using ESRT II with 2 1TB SATA drives configured...
View Articles1200BTL led de exclamação fica acesso
Servidor com led de tus do sistema acesso direto. O que pode ser?
View ArticleRe: Can I get the snmp subagent for the hardware S5000PHB .
Gopi, The S5000PHB server board was the baseboard for the carrier grade server TIGW1U. I believe it was in 2008 that Kontron purchased the Intel carrier hardware unit. You can find information for the...
View Article2600GZ based server, bios issues, fan speed
We are basing an appliance on the intel , which is now 3 seperate components instead of a single sku:R2224GZ4GC, RMS25CB080 & RES2CV360 the bios that ships with the older R2224GZ4GCSAS sku has an...
View ArticleRe: IMS MFSYS25 - Bad sector found
The simple way is to make the new drive as hot spare first, and then remove the faulty one. But if you don't have any free slot for the new drive, follow the steps below: 1. If the disk is already...
View ArticleRe: Is my plan to increase raid drive sizes and change partition sizes workable?
Well it's quite possible that the bootable DVD with Acronis doesn't have embedded driver for ESRT2, which means when you boot from that DVD it won't even see the RAID volumes... Before making any...
View ArticleRe: 2600GZ based server, bios issues, fan speed
Try the steps in http://www.intel.com/support/motherboards/server/sb/CS-022809.htm. If issue not fixed, check for errors in the SEL.
View ArticleRe: IMS MFSYS25 - Bad sector found
Hi.assuming you have a spare slot available you could just add the drive, define it as a spare (non-revertable !) and then "force offline" the old drive. Unfortunately you have to run the RAID in...
View ArticleRe: Intel Server Motherboards interfacing with Redundant Power Supplies from...
I did not find a way to use IPMItool on windows, appears it will need to be recompiled. I tried the ipmiutil but so far have not uncovered all the information I needed to do the commands you spelled...
View Article