INTEL P4308RPLSHDR SERVER SYSTEM WITH RSBL080

$
0
0

I have 2 servers like this.  Issue with both is that hotspares fail on patrol reads.  I narrowed it down to the fact they go from power transition to unconfigured bad state when patrol read starts.  I have "worked around it" by configuring controller not to put hotspares in low power state.

 

On a side note I have another SERVER CHASSIS P4308XXMHGC with ITL S2400SC2 SERVER MB and RSBL040 that has no problem spinning up hotspares for patrol reads.

All 3 server use the same controller firmware and using the same model/size hard drives and operating systems.  My best guess is there may be an issue with the P4308RPLSHDR backplane firmware, but I see no update to it.